Trane Furnace 2 flashes
What this problem usually means
Trane uses this flash count on two different control families, so note which LED is flashing (red LED = single-stage control; green LED = two-stage control). On single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), 2 flashes means system lockout — ignition retries or recycles were exceeded, so the furnace tried to light several times, failed, and locked out. On two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), 2 flashes instead means a pressure switch stuck closed or an inducer error.
Likely causes
- Single-stage models: failed or cracked hot surface igniter
- Single-stage models: dirty flame sensor not proving flame
- Single-stage models: gas supply off or low gas pressure
- Two-stage models: pressure switch stuck closed
- Two-stage models: moisture or debris in the pressure switch or its hose
- Two-stage models: inducer motor fault
How to fix it — step by step
- Note the code and which LED is flashing before resetting, because a power cycle erases it
- Confirm the thermostat is set to Heat and calling for heat
- Check that the gas shutoff valve to the furnace is open and other gas appliances work
- Check outdoor vent and intake terminations for snow, ice or debris, and check the condensate drain for clogs or freezing
- Replace a dirty air filter, which can contribute to shutdowns
- Turn furnace power off for 30 seconds and back on once to clear the lockout; if the code returns, stop resetting and call a technician
Parts that commonly fix it
- hot surface igniter - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- gas valve - Shop at RepairClinic
- pressure switch - Shop at RepairClinic
- inducer motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.