Trane Furnace 4 flashes
What this problem usually means
On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes this count: open limit switch — a temperature limit opened because the furnace overheated.
Likely causes
- Dirty or clogged air filter restricting airflow
- Closed or blocked supply registers and returns
- Weak or failed blower motor
- Failed limit switch
How to fix it — step by step
- Turn the thermostat down and let the furnace cool
- Replace the air filter if it is dirty
- Open all supply registers and make sure returns are not blocked by furniture
- Restore power and call for heat once to see if it runs
- If the code repeats, call a technician — repeated limit trips can damage the heat exchanger
Parts that commonly fix it
- limit switch - Shop at RepairClinic
- blower motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.