Trane Furnace 8 flashes

What this problem usually means

On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes this count: low flame sense signal — flame is present but the flame sensor signal is too weak for reliable operation.

Likely causes

  1. Dirty or oxidized flame sensor
  2. Poor burner ground
  3. Weak flame from dirty burners or low gas pressure

How to fix it — step by step

  1. Replace the air filter and confirm all registers are open
  2. Reset power once and observe whether the furnace completes a full heat cycle
  3. Note if the furnace lights then shuts off after a few seconds — a classic weak flame-signal pattern
  4. Call a technician to clean or replace the flame sensor and check burner ground; sensor cleaning is burner-compartment work

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.