Trane Furnace 7 flashes
What this problem usually means
Trane uses this flash count on two different control families, so note which LED is flashing (red LED = single-stage control; green LED = two-stage control). On single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), 7 flashes means a gas valve circuit error — the control detects a fault in the gas valve circuit, such as voltage present when the valve should be off. On two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), 7 flashes means external lockout — retries exceeded, after the furnace failed to establish flame through all ignition retries.
Likely causes
- Single-stage models: shorted gas valve wiring
- Single-stage models: failed gas valve solenoid
- Single-stage models: failed control board gas valve relay
- Two-stage models: failed hot surface igniter
- Two-stage models: dirty flame sensor
- Two-stage models: gas supply off or interrupted
How to fix it — step by step
- Turn furnace power off and note the code and which LED is flashing for the technician
- Confirm the gas shutoff valve to the furnace is open and other gas appliances work
- Do not attempt to test or rewire the gas valve circuit
- If you smell gas, leave the house and call the gas utility from outside
- Call a technician to test the gas valve, igniter, flame sensor and control board
Parts that commonly fix it
- gas valve - Shop at RepairClinic
- control board - Shop at RepairClinic
- hot surface igniter - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.