Trane Furnace 5 flashes

What this problem usually means

Trane uses this flash count on two different control families, so note which LED is flashing (red LED = single-stage control; green LED = two-stage control). On single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), 5 flashes means flame sensed when no flame should be present — the control sees a flame signal while the gas valve should be closed, which is a safety fault. On two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), 5 flashes means an open rollout switch or an open control fuse.

Likely causes

  1. Single-stage models: gas valve leaking or stuck open
  2. Single-stage models: shorted or damaged flame sensor wiring
  3. Single-stage models: failed control board misreading the flame signal
  4. Two-stage models: flame rollout from a blocked or cracked heat exchanger
  5. Two-stage models: blocked venting causing a rollout trip
  6. Two-stage models: blown control board fuse from a low-voltage short

How to fix it — step by step

  1. Turn the furnace power switch off and close the gas shutoff to the furnace
  2. Do not keep resetting or trying to run the furnace — both meanings of this code are safety faults, and a tripped rollout switch can signal a dangerous heat exchanger problem
  3. If you smell gas, leave the house and call the gas utility from outside
  4. Call a technician to find the cause before the furnace runs again

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.