What this problem usually means
On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: igniter failure — the igniter circuit did not perform as expected during the ignition sequence.
Likely causes
- Cracked or burned-out hot surface igniter
- Loose igniter connector
- Failed igniter output on the control board
How to fix it — step by step
- Confirm the thermostat is calling for heat
- Reset power once and listen: inducer runs but no glow or ignition points to the igniter
- Stop after one reset if the code returns
- Call a technician to test and replace the igniter
Parts that commonly fix it
- hot surface igniter - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.