Payne Furnace Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 25 codes covered.
Shop Payne Furnace parts at RepairClinic
- 10.1 — L1 polarity fault on the Payne PG80MSU (80% furnace with 3-digit display). The LED flashes rapidly and the display reads 10.1: the polarity…
- 11 — No previous code. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 11 means nothing is stored in the control's fault…
- 12 — Blower on after power up - normal operation on Payne furnaces such as the PG92ESA, PG95ESA, PG96VTA and PG80MSU. The blower runs for 90…
- 13 — Limit circuit lockout. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 13 occurs when the limit or flame rollout switch…
- 14 — Ignition lockout. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 14 means the furnace failed to ignite the gas and prove…
- 14.2 — Flame lost lockout on the Payne PG80MSU (3-digit display model). The LED flashes major code 14 while the display reads 14.2: the flame…
- 21 — Gas heating lockout. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 21 means 24 VAC was sensed on the gas valve when it…
- 22 — Abnormal flame-proving signal. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 22 means flame is proved while the gas…
- 23 — Pressure switch did not open. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 23 means the pressure switch was still…
- 23.3 — Over pressure at start-up on the Payne PG80MSU (3-digit display model with pressure transducer). The LED flashes major code 23 while the…
- 24 — Secondary voltage fuse is open. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 24 means the 24 V secondary voltage fuse…
- 25 — Invalid model selection or setup error, documented on the Payne PG96VTA variable-speed two-stage furnace. If code 25 flashes only 4 times…
- 26.1 — Loose factory wiring on Payne furnaces with a 3-digit status display. The LED flashes major code 26 while the display reads 26.1: a jumper…
- 27 — Super plug program fault on Payne furnaces with a 3-digit status display. The program in the super plug is missing, not recognized, or…
- 31 — Pressure switch did not close or reopened. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA this is the vent pressure switch (the…
- 31.4 — Loss of pressure before the blower comes on, on the Payne PG80MSU (3-digit display model with pressure transducer). The LED flashes major…
- 32 — Low-heat pressure switch did not close or reopened, on Payne two-stage furnaces such as the PG96VTA (also listed for PG92ESA/PG95ESA). If…
- 33 — Limit circuit fault. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 33 means the high-limit or flame rollout switch is…
- 34 — Ignition proving failure. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 34 means flame was not sensed during the trial…
- 34.2 — Flame lost after successful ignition on the Payne PG80MSU (3-digit display model). The LED flashes major code 34 while the display reads…
- 42 — Inducer RPM fault on the Payne PG80MSU (80% furnace with 3-digit display and pressure transducer). Minor code 42.1 means no RPM feedback at…
- 43 — Low-heat pressure switch open while the high-heat pressure switch is closed, on the Payne PG96VTA two-stage furnace - a contradictory…
- 45 — Control circuitry lockout (on some Payne service labels worded 'replace control'). The control board has detected an internal failure in…
- 46.1 — Momentary loss of power on Payne furnaces with a 3-digit status display. The LED flashes major code 46 while the display reads 46.1…
- Rapid flashing — On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, an amber status LED blinking rapidly with no pause means the line-voltage (115…