Payne Furnace 42 Error Code

What the 42 code means

Inducer RPM fault on the Payne PG80MSU (80% furnace with 3-digit display and pressure transducer). Minor code 42.1 means no RPM feedback at start-up or before ignition proved, 42.2 means the RPM signal was lost for 5 seconds after ignition proved, and 42.3 means the inducer is exceeding its model-specific RPM limit.

Likely causes

  1. Failed inducer motor
  2. Improper vent sizing
  3. Restricted combustion air supply
  4. Loose or damaged inducer motor wiring

How to fix it — step by step

  1. Check the outdoor intake and exhaust pipes for snow, ice, leaves or a nest blocking them
  2. Note the code for the technician
  3. Cycle power once at the service switch
  4. If 42 returns, call a technician - a furnace that cannot run its inducer cannot vent combustion gases safely

Parts that commonly fix the 42 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Payne furnace error codes

See all Payne furnace codes & guides →