Payne Furnace 33 Error Code

What the 33 code means

Limit circuit fault. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 33 means the high-limit or flame rollout switch is open - the furnace is overheating or airflow is restricted. The blower runs 4 minutes or until the switch remakes; if it stays open longer than 3 minutes the code becomes lockout 13, and the rollout switch requires manual reset.

Likely causes

  1. Dirty filter or restricted duct system
  2. Loose blower wheel
  3. Defective limit switch or connections
  4. Improper gas input adjustment
  5. Flame rollout switch tripped

How to fix it — step by step

  1. Check the air filter and replace it if dirty - this is the most common cause
  2. Open all supply registers and clear blocked return grilles
  3. Let the furnace cool, then cycle power once at the service switch
  4. Check outdoor vent terminations for blockage
  5. If 33 returns, or you suspect the rollout switch tripped, stop and call a technician - never reset a rollout switch without finding the cause

Parts that commonly fix the 33 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Payne furnace error codes

See all Payne furnace codes & guides →