Payne Furnace 14.2 Error Code
What the 14.2 code means
Flame lost lockout on the Payne PG80MSU (3-digit display model). The LED flashes major code 14 while the display reads 14.2: the flame signal was lost three times after the heating blower on-delay. The control auto-resets after 3 hours; see code 34.3.
Likely causes
- Incorrect manifold pressure or gas firing rate
- Gas inlet pressure fluctuations
- Improper pressure transducer operation
- Flame sensing problem
How to fix it — step by step
- Check that the air filter is clean and vents are open
- Confirm other gas appliances are working normally
- Do not keep resetting the furnace
- Call a technician to verify gas pressure and flame sensing before running the furnace
Parts that commonly fix the 14.2 code
- flame sensor - Shop at RepairClinic
- gas valve - Shop at RepairClinic
- pressure transducer - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.