Payne Furnace 10.1 Error Code
What the 10.1 code means
L1 polarity fault on the Payne PG80MSU (80% furnace with 3-digit display). The LED flashes rapidly and the display reads 10.1: the polarity of the incoming 115 V power is reversed and the furnace will not operate.
Likely causes
- Line-voltage hot and neutral reversed at a junction box, outlet or the furnace
- Improper 24 V transformer phasing on twinned furnaces
How to fix it — step by step
- Turn the furnace off at the service switch and leave it off
- Note the code for the technician
- Do not open junction boxes or swap wires yourself - this is live 115 V wiring
- Call an HVAC technician or electrician to correct the polarity
Parts that commonly fix the 10.1 code
This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.