- 10.1 — L1 polarity fault on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes rapidly and the display…
- 11 — No previous code. On Carrier furnaces with the two-digit LED status code system, code 11 means no fault is stored in the control's memory…
- 12 — Blower on after power up. On Carrier 58-series furnaces this is normal operation: if power is restored while the thermostat is calling for…
- 13 — Limit circuit lockout. On Carrier 58-series furnaces, code 13 occurs when a limit, draft safeguard, flame rollout or blocked vent switch…
- 14 — Ignition lockout. On Carrier 58-series furnaces, code 14 means the furnace failed to ignite the gas and prove flame after repeated attempts…
- 14.2 — Flame lost lockout on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 14 while the…
- 14.3 — Flame lost lockout on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 14 while the…
- 15 — Blower motor lockout on Carrier variable-speed two-stage furnaces such as the 58CVA/58MVP. The blower failed to reach 250 RPM or failed to…
- 21 — Gas heating lockout. On Carrier 58-series furnaces, code 21 means the control sensed voltage on the gas valve when it should not be there…
- 22 — Abnormal flame-proving signal (false flame). On Carrier 58-series furnaces, code 22 means flame is being sensed while the gas valve is…
- 23 — Pressure switch did not open. On Carrier 58-series furnaces, code 23 means the vent pressure switch was still closed when the control…
- 24 — Secondary voltage fuse is open. On Carrier 58-series furnaces, code 24 means the 3-amp fuse protecting the 24 VAC secondary circuit on the…
- 25 — Invalid model selection or setup error on Carrier variable-speed two-stage furnaces such as the 58CVA/58MVP. The model plug is missing or…
- 31 — Pressure switch did not close or reopened. On single-stage Carrier furnaces such as the 58ST this is the main vent pressure switch; on…
- 32 — Low-heat pressure switch did not close or reopened, on two-stage Carrier furnaces such as the 58CTA and 58CVA. If the switch stays open…
- 33 — Limit circuit fault. On Carrier 58-series furnaces, code 33 means a limit, draft safeguard, flame rollout or blocked vent switch is open -…
- 34 — Ignition proving failure. On Carrier 58-series furnaces, code 34 means flame was not sensed during the trial for ignition; the control…
- 41 — Blower motor fault on Carrier variable-speed furnaces such as the 58CVA/58MVP. The blower failed to reach 250 RPM or failed to communicate…
- 42 — Inducer motor fault on Carrier variable-speed two-stage furnaces such as the 58MVP/58UVB. The inducer did not start within about 20 seconds…
- 43 — Low-heat pressure switch open while the high-heat pressure switch is closed - a contradictory pressure switch state on two-stage Carrier…
- 44 — Blower calibration fault on Carrier variable-speed furnaces such as the 58MVP. The calculated blower speed is below 250 RPM or above 1300…
- 45 — Control circuitry lockout (on some Carrier service labels worded 'replace control'). The control board has detected an internal failure - a…
- 45.1 — Control failure on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 45 while the…
- 45.2 — Control failure on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 45 while the…
- 45.3 — Control failure on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 45 while the…
- 46.1 — Momentary loss of power on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 46 while…
- Rapid flashing — On Carrier 58-series furnaces, a status LED that flashes rapidly and continuously with no pause means the line-voltage (115 VAC) polarity…