Carrier Furnace 33 Error Code
What the 33 code means
Limit circuit fault. On Carrier 58-series furnaces, code 33 means a limit, draft safeguard, flame rollout or blocked vent switch is open - most often because the furnace is overheating from poor airflow. The blower runs for 4 minutes to cool the furnace; if the switch stays open longer than 3 minutes the code changes to lockout 13, and the flame rollout switch needs a manual reset.
Likely causes
- Dirty filter or restricted duct system
- Defective blower motor or capacitor
- Loose blower wheel
- Restricted vent or improper vent sizing
- Flame rollout switch open from inadequate combustion air
How to fix it — step by step
- Check the air filter and replace it if dirty - this is the most common cause
- Open all supply registers and clear blocked return grilles
- Let the furnace cool, then cycle power once at the service switch
- Check outdoor vent terminations for blockage
- If 33 returns, or you suspect the rollout switch tripped, stop and call a technician - never reset a rollout switch without finding the cause