Carrier Furnace 33 Error Code

What the 33 code means

Limit circuit fault. On Carrier 58-series furnaces, code 33 means a limit, draft safeguard, flame rollout or blocked vent switch is open - most often because the furnace is overheating from poor airflow. The blower runs for 4 minutes to cool the furnace; if the switch stays open longer than 3 minutes the code changes to lockout 13, and the flame rollout switch needs a manual reset.

Likely causes

  1. Dirty filter or restricted duct system
  2. Defective blower motor or capacitor
  3. Loose blower wheel
  4. Restricted vent or improper vent sizing
  5. Flame rollout switch open from inadequate combustion air

How to fix it — step by step

  1. Check the air filter and replace it if dirty - this is the most common cause
  2. Open all supply registers and clear blocked return grilles
  3. Let the furnace cool, then cycle power once at the service switch
  4. Check outdoor vent terminations for blockage
  5. If 33 returns, or you suspect the rollout switch tripped, stop and call a technician - never reset a rollout switch without finding the cause

Parts that commonly fix the 33 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.