Carrier Furnace 45.2 Error Code

What the 45.2 code means

Control failure on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 45 while the display reads 45.2: the gas valve relay on the control board will not close, so the board can no longer control gas flow reliably.

Likely causes

  1. Failed gas valve relay on the control board
  2. Internal control board fault - the manual's remedy for this code is to replace the control

How to fix it — step by step

  1. Turn the furnace off at the service switch and leave it off
  2. Do not cycle power repeatedly trying to clear it
  3. Do not touch the gas valve
  4. Call a technician - the control board must be replaced

Parts that commonly fix the 45.2 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Carrier furnace error codes