Carrier Furnace 13 Error Code
What the 13 code means
Limit circuit lockout. On Carrier 58-series furnaces, code 13 occurs when a limit, draft safeguard, flame rollout or blocked vent switch stays open longer than 3 minutes (on some two-stage models, also after repeated limit trips in high heat). The control locks out and auto-resets after 3 hours; see code 33 for the underlying fault.
Likely causes
- Repeated overheating from restricted airflow (dirty filter, blocked ducts)
- Flame rollout switch tripped
- Defective limit switch or loose connections
- Restricted or improperly sized vent
How to fix it — step by step
- Turn the thermostat down and let the furnace cool completely
- Check the air filter and replace it if it is dirty
- Open all supply registers and make sure return grilles are not blocked
- Wait for the 3-hour auto-reset or cycle power once at the service switch
- If 13 returns, stop resetting and call a technician - a tripped flame rollout switch must be diagnosed, never just reset
Parts that commonly fix the 13 code
- limit switch - Shop at RepairClinic
- flame rollout switch - Shop at RepairClinic
- blower motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.