What the E270 code means

On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E270 is a Watchguard soft lockout — flame failed to ignite through all retries (five failed tries), so the furnace shut down and will retry after the Watchguard period.

Likely causes

  1. Failed hot surface igniter
  2. Dirty flame sensor
  3. Gas supply off or interrupted
  4. Dirty filter or blocked drain interrupting the sequence

How to fix it — step by step

  1. Confirm the gas shutoff is open and other gas appliances work
  2. Replace a dirty air filter and check the condensate drain
  3. Wait out the Watchguard or reset power once
  4. If it locks out again, call a technician to test the igniter, sensor and gas valve