Lennox Furnace 2 + 5 Error Code
What the 2 + 5 code means
On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 5 means the high pressure switch failed open — the second-stage (high-fire) pressure switch did not close.
Likely causes
- Blocked vent at high fire
- Clogged condensate drain
- Weak inducer on second stage
- Failed high pressure switch
How to fix it — step by step
- Clear the outdoor vent and intake terminations
- Check the condensate drain for clogs or freezing
- Reset power once and note if the fault happens only on a big heat demand
- Call a technician to test the high pressure switch and inducer
Parts that commonly fix the 2 + 5 code
- pressure switch - Shop at RepairClinic
- inducer motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.