Lennox Furnace 2 + 5 Error Code

What the 2 + 5 code means

On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 5 means the high pressure switch failed open — the second-stage (high-fire) pressure switch did not close.

Likely causes

  1. Blocked vent at high fire
  2. Clogged condensate drain
  3. Weak inducer on second stage
  4. Failed high pressure switch

How to fix it — step by step

  1. Clear the outdoor vent and intake terminations
  2. Check the condensate drain for clogs or freezing
  3. Reset power once and note if the fault happens only on a big heat demand
  4. Call a technician to test the high pressure switch and inducer

Parts that commonly fix the 2 + 5 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.