Lennox Furnace 4 + 1 Error Code
What the 4 + 1 code means
On Lennox G61MPV furnaces with the SureLight control, flash code 4 + 1 is a Watchguard lockout — the furnace exceeded the maximum number of ignition retries and will wait (about an hour) before trying again.
Likely causes
- Failed hot surface igniter
- Dirty flame sensor
- Gas supply off or interrupted
- Blocked condensate drain preventing ignition sequence
How to fix it — step by step
- Note any earlier flash code, since Watchguard is the result, not the root cause
- Confirm the gas shutoff is open and the filter is clean
- Wait for the Watchguard period to end or reset power once
- If it locks out again, call a technician to test the igniter, flame sensor and gas valve
Parts that commonly fix the 4 + 1 code
- hot surface igniter - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.