Lennox Furnace E241 Error Code

What the E241 code means

On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E241 means flame out of sequence and still present — the control senses flame when the gas valve should be closed. Lennox's documented first step is shutting off the gas.

Likely causes

  1. Gas valve leaking or stuck open
  2. Failed control board
  3. Shorted flame-sense wiring

How to fix it — step by step

  1. Shut off the gas supply to the furnace and turn furnace power off
  2. Do not try to restart the furnace
  3. If you smell gas, leave the house and call the gas utility from outside
  4. Call a technician to test the gas valve before the furnace is used again

Parts that commonly fix the E241 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.