Lennox Furnace E227 Error Code

What the E227 code means

On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E227 means the low pressure switch opened in run mode — draft was proved, then lost while the furnace was running (seven-segment wording: pressure switch opened during ignition or run).

Likely causes

  1. Vent or intake blocked during run
  2. Condensate backing up during run
  3. Failing inducer motor
  4. Intermittent pressure switch

How to fix it — step by step

  1. Clear the outdoor terminations
  2. Check the condensate drain hose for clogs, kinks or freezing
  3. Reset power once and watch a full cycle
  4. Call a technician if it recurs, to test draft and the inducer

Parts that commonly fix the E227 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.