Trane Furnace E2.2 Error Code
What the E2.2 code means
On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E2.2 is recycles exceeded — flame was sensed then lost repeatedly (one-hour lockout after 10 recycles).
Likely causes
- Dirty flame sensor dropping the flame signal
- Low or unstable gas pressure
- Dirty burners or poor burner ground
How to fix it — step by step
- Replace the air filter and open all registers
- Reset power once after the lockout and watch one full cycle
- Note whether the burners light and then go out within seconds
- Call a technician to clean/test the flame sensor and check gas pressure if it recurs
Parts that commonly fix the E2.2 code
- flame sensor - Shop at RepairClinic