Rheem Furnace 1 blink

What this problem usually means

Soft lockout for one hour on older Rheem/Ruud furnaces with the blinking status LED board (per Rheem Tech Tip TP0002, not modulating/two-stage/LXE models). Four failed ignition tries or four flame losses in one call caused the lockout.

Likely causes

  1. failed ignition attempts
  2. flame loss during the cycle
  3. gas supply problem
  4. faulty igniter or dirty flame sensor

How to fix it — step by step

  1. Check the thermostat is set to Heat and the furnace power switch and breaker are on
  2. Confirm the manual gas shutoff valve near the furnace is open (handle parallel to the pipe)
  3. Turn power off for 30 seconds, then back on, and allow one retry cycle
  4. Do not keep resetting a furnace that repeatedly fails to light
  5. If it locks out again, call a licensed HVAC technician and note the code

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Rheem furnace problems