Rheem Furnace 1 blink
What this problem usually means
Soft lockout for one hour on older Rheem/Ruud furnaces with the blinking status LED board (per Rheem Tech Tip TP0002, not modulating/two-stage/LXE models). Four failed ignition tries or four flame losses in one call caused the lockout.
Likely causes
- failed ignition attempts
- flame loss during the cycle
- gas supply problem
- faulty igniter or dirty flame sensor
How to fix it — step by step
- Check the thermostat is set to Heat and the furnace power switch and breaker are on
- Confirm the manual gas shutoff valve near the furnace is open (handle parallel to the pipe)
- Turn power off for 30 seconds, then back on, and allow one retry cycle
- Do not keep resetting a furnace that repeatedly fails to light
- If it locks out again, call a licensed HVAC technician and note the code
Parts that commonly fix it
- hot surface igniter - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.