Rheem Furnace 13 Error Code
What the 13 code means
Flame lost on Rheem furnaces with the 7-segment diagnostic display. Flame was established and then lost during the heating cycle; five losses in a row cause a one-hour lockout with code 10.
Likely causes
- dirty flame sensor
- low gas pressure
- faulty gas valve
- interrupted gas supply
How to fix it — step by step
- Check the thermostat is set to Heat and the furnace power switch and breaker are on
- Confirm the manual gas shutoff valve near the furnace is open (handle parallel to the pipe)
- Turn power off for 30 seconds, then back on, and allow one retry cycle
- Do not keep resetting a furnace that repeatedly fails to light
- If it locks out again, call a licensed HVAC technician and note the code
Parts that commonly fix the 13 code
- flame sensor - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.