Pentair Pool heater ERR IGN Error Code
What the ERR IGN code means
On Pentair MasterTemp gas pool heaters, ERR IGN means the Ignition Control Module was not able to ignite the heater. Clear it by pressing the HEATER OFF button.
Likely causes
- gas supply off or low
- failed igniter
- flame sensor fault
- ignition control module fault
How to fix it — step by step
- Press HEATER OFF to clear the error and note the code; if you smell gas, stop and call your gas utility
- Check from outside the cabinet that the gas shutoff is open
- Make sure the pump is running with good flow
- Try one restart
- If ERR IGN returns, call a licensed pool/spa or gas technician - do not open the gas train
Parts that commonly fix the ERR IGN code
- igniter - Shop at RepairClinic
- ignition control module - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.