Pentair Pool heater ERR PS Error Code

What the ERR PS code means

On Pentair MasterTemp (and Sta-Rite Max-E-Therm) gas pool heaters, ERR PS means the water pressure switch is open - no water flow through the heater. The manual says the error clears and normal operation resumes when water flow is established.

Likely causes

  1. circulation pump off or low flow
  2. dirty filter or closed valves
  3. clogged baskets
  4. failed water pressure switch

How to fix it — step by step

  1. Make sure the circulation pump is running
  2. Clean or backwash the filter and empty skimmer and pump baskets
  3. Open all valves to the heater fully
  4. Confirm strong flow - the code should clear by itself when flow returns
  5. If ERR PS persists with good flow, call a pool/spa technician about the pressure switch

Parts that commonly fix the ERR PS code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Pentair pool heater error codes

See all Pentair pool heater codes & guides →