Pentair Pool heater SUCTION TH OPEN Error Code

What the SUCTION TH OPEN code means

On Pentair UltraTemp heat pump pool heaters, SUCTION TH OPEN means the defrost (suction) thermistor circuit is open.

Likely causes

  1. failed defrost thermistor
  2. disconnected or broken thermistor wiring
  3. connector fault

How to fix it — step by step

  1. Turn the heat pump off and note the alarm
  2. Cycle power once and try one restart
  3. Do not open the cabinet to test the thermistor
  4. If the alarm returns, call a pool/spa technician to test and replace the defrost thermistor

Parts that commonly fix the SUCTION TH OPEN code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Pentair pool heater error codes

See all Pentair pool heater codes & guides →