Pentair Pool heater FIVE ALARMS Error Code

What the FIVE ALARMS code means

On Pentair UltraTemp heat pump pool heaters, FIVE ALARMS indicates that 5 faults have occurred in one hour. It automatically resets in one hour or can be manually reset by pressing the ON/OFF button.

Likely causes

  1. five alarms of any kind within one hour
  2. an underlying repeating fault such as low flow or a refrigerant pressure alarm

How to fix it — step by step

  1. Press ON/OFF to clear the alarm, as the manual directs, or wait one hour for auto-reset
  2. Watch the display for the next underlying alarm - that code is the real fault
  3. Fix the simple cause first if it is flow-related: pump on, filter clean, valves open
  4. If alarms keep recurring, stop resetting and call a pool/spa technician with the underlying code

Parts that commonly fix the FIVE ALARMS code

This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Pentair pool heater error codes

See all Pentair pool heater codes & guides →