Maytag Dryer F4 E3 Error Code

What the F4 E3 code means

Restricted airflow (the F-code form of AF): the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The dryer continues to run while the code is shown.

Likely causes

  1. Clogged lint screen
  2. Vent crushed, kinked or clogged with lint
  3. Vent run with too many turns
  4. Blocked outside vent hood

How to fix it — step by step

  1. Clean the lint screen thoroughly
  2. Check the vent behind the dryer is not crushed or kinked
  3. Clean lint from the whole vent run to the outside hood
  4. Touch any key to clear the code, then run a Timed Dry heated cycle to check drying

Parts that commonly fix the F4 E3 code

This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.