Maytag Dryer Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 13 codes covered.
Shop Maytag Dryer parts at RepairClinic
- AF — Restricted airflow: the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The dryer keeps running while…
- F1 E1 — Motor relay stuck on the electronic control board.
- F2 E1 — A button on the user interface control is stuck, so the control reads it as pressed continuously.
- F3 E1 — Exhaust thermistor failure: the sensor that reads exhaust temperature has failed or its signal is out of range.
- F3 E2 — Moisture sensor failure: the sensor bars inside the drum are not reading the load's moisture correctly.
- F3 E3 — Inlet thermistor failure: the sensor that reads incoming air temperature has failed.
- F4 E1 — Heater relay failure (also shown as F4 E2 on some models): the control's heater relay is not switching the heating element correctly, so…
- F4 E3 — Restricted airflow (the F-code form of AF): the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The…
- F4 E4 — Voltage supply error: the L2 leg of the 240-volt power supply is missing, so the heater circuit has no power.
- F6 E2 — Communication failure between the electronic control board and the user interface control (also shown as F6 E3).
- L2 — Low or no line voltage: there may be a problem with the home power supply, keeping the dryer's heater from turning on. The dryer continues…
- Loc — The Control Lock is enabled, so the dryer controls are locked.
- PF — Power failure: the drying cycle has been interrupted by a power failure.