Bryant Furnace 33 Error Code
What the 33 code means
Limit or flame rollout switch is open. On Bryant furnaces, code 33 means a switch in the limit circuit opened - most often because the furnace is overheating from poor airflow. If the switch stays open, the code escalates to lockout 13, and a tripped flame rollout switch needs a manual reset after the cause is found.
Likely causes
- Dirty filter or restricted duct system
- Closed or blocked registers
- Defective blower motor or capacitor
- Flame rollout switch open from a venting or combustion air problem
How to fix it — step by step
- Check the air filter and replace it if dirty - this is the most common cause
- Open every supply register and clear blocked return grilles
- Let the furnace cool, then cycle power once at the service switch
- Check outdoor vent terminations for blockage
- If 33 returns, or you suspect the rollout switch tripped, stop and call a technician
Parts that commonly fix the 33 code
- limit switch - Shop at RepairClinic
- flame rollout switch - Shop at RepairClinic
- blower motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.