Bryant Furnace 41 Error Code

What the 41 code means

Blower motor fault on Bryant furnaces with variable-speed blower motors. The blower did not reach the required speed or lost communication with the control.

Likely causes

  1. Failed blower motor or motor module
  2. Loose blower motor wiring or communication connection
  3. Jammed or seized blower wheel

How to fix it — step by step

  1. Make sure the blower access door is fully closed and latched
  2. Turn power off at the service switch for one minute, then back on once
  3. Replace a severely clogged air filter
  4. If 41 returns, call a technician - variable-speed blower motors need professional testing

Parts that commonly fix the 41 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.