York Furnace 3 red flashes
What this problem usually means
The pressure switch contact did not close after the inducer was energized on York furnaces with the red/green/amber LED control, so ignition does not start.
Likely causes
- faulty inducer motor
- blocked vent pipe
- broken pressure switch hose
- faulty pressure switch
- blocked condensate drain on condensing models
How to fix it — step by step
- Check the thermostat is set to Heat and calling for heat
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
- Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
- If the code returns, stop resetting and call a licensed HVAC technician
Parts that commonly fix it
- pressure switch - Shop at RepairClinic
- inducer motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.