Jandy Pool heater FAULT- HIGH LIMIT Error Code

What the FAULT- HIGH LIMIT code means

On Jandy JXi gas pool heaters, FAULT- HIGH LIMIT means water inside the heater exceeded its internal high-limit setting, or a high-limit switch has faulted. The JXi has two high limits, about 135F at the heat exchanger first pass and 150F at the outlet.

Likely causes

  1. restricted water flow through the heater
  2. dirty filter or pump running too slow
  3. stuck thermal regulator valve
  4. faulty high-limit switch

How to fix it — step by step

  1. Turn the heater off and let the water in the heater cool
  2. Confirm the pump is running with strong flow and clean the filter
  3. Check valves are open and pump speed is adequate
  4. Try the heater once after it has cooled
  5. If the fault repeats, stop and call a pool technician to test the high-limit switches

Parts that commonly fix the FAULT- HIGH LIMIT code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Jandy pool heater error codes

See all Jandy pool heater codes & guides →