Raypak Pool heater Ignition Lockout
What this problem usually means
On Raypak Digital gas pool heaters (206A-406A), Ignition Lockout means the automatically lighted pilot did not establish or hold flame in the allowed trial time - shown as No pilot sensed, or the pilot went out during the main burner trial (Main Ign Failure).
Likely causes
- gas shutoff closed or low gas supply
- dirty pilot orifice
- faulty igniter or spark lead
- failed pilot or gas valve
How to fix it — step by step
- Confirm the manual gas shutoff valve by the heater is open
- Check the vent is clear of debris from outside
- Reset the heater once only
- If it locks out again, turn it off and call a qualified gas pool heater technician
Parts that commonly fix it
- igniter - Shop at RepairClinic
- pilot assembly - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.