Lennox Furnace DS1 slow flash, DS2 fast flash
What this problem usually means
On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), DS1 slow flash with DS2 fast flash means a low flame signal (below 0.2 microamps) — the flame sensor signal is too weak.
Likely causes
- Dirty or oxidized flame sensor
- Poor burner ground
- Weak flame from dirty burners
How to fix it — step by step
- Replace the air filter and open all registers
- Note if the furnace runs but short-cycles
- Reset power once and observe a full cycle
- Call a technician to clean or replace the flame sensor and measure flame current
Parts that commonly fix it
- flame sensor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.