Jacuzzi Hot tub FL--3 Error Code

What the FL--3 code means

On Jacuzzi J-300 Collection hot tubs, FL--3 (FLOW ERROR TOGGLE) means the flow switch is behaving erratically, switching on and off. The heater deactivates and Jets Pump 1 may also deactivate.

Likely causes

  1. dirty filter cartridge
  2. incorrect water level
  3. intermittent flow switch
  4. air in the circulation line

How to fix it — step by step

  1. Clean the filter cartridge thoroughly
  2. Correct the water level to above the jets and below the lowest pillow
  3. Turn power off at the breaker, then back on to reset
  4. If FL--3 returns, contact your Jacuzzi dealer or a qualified spa technician

Parts that commonly fix the FL--3 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Jacuzzi hot tub error codes