Goodman Furnace 3 flashes

What this problem usually means

Pressure switch stuck open on Goodman GMES96-series furnaces. The inducer ran but the pressure switch never closed to prove draft, so ignition does not start.

Likely causes

  1. blocked vent or intake pipe
  2. clogged condensate drain or trap
  3. weak or failed inducer motor
  4. cracked or disconnected pressure switch hose
  5. faulty pressure switch

How to fix it — step by step

  1. Check the thermostat is set to Heat and calling for heat
  2. Check the outdoor vent and intake pipes are clear of snow, ice or debris
  3. On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
  4. Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
  5. If the code returns, stop resetting and call a licensed HVAC technician

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.