What the E4 code means
On GE Profile DPVH890 dryers (technical service manual): Inlet Open - the inlet thermistor circuit is open; check and replace if necessary.
Likely causes
- Open/failed inlet thermistor
- Disconnected thermistor connector
- Broken wire in the thermistor harness
How to fix it — step by step
- Unplug the dryer and let it cool
- Try one cycle after restoring power
- If E4 returns, arrange service for thermistor/harness replacement
Parts that commonly fix the E4 code
- inlet thermistor - Shop at RepairClinic
- wire harness - Shop at RepairClinic