GE Dryer Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 33 codes covered.
Shop GE Dryer parts at RepairClinic
- 001 — On GE GFD model dryers: the inlet thermistor (temperature sensor) is defective - 001 and 003 both flag the inlet thermistor, which measures…
- 002 — On GE GFD model dryers: the outlet thermistor (temperature sensor) is defective - 002 and 004 both flag the outlet thermistor, which…
- 003 — On GE GFD model dryers: the inlet thermistor (temperature sensor) is defective - the second of the two inlet-thermistor codes (001 or 003).
- 004 — On GE GFD model dryers: the outlet thermistor (temperature sensor) is defective - the second of the two outlet-thermistor codes (002 or…
- 005 — On GE GFD model dryers: the main control board is defective.
- 006 — On GE GFD model dryers: a button on the control panel is stuck or not functioning.
- 007 — On GE GFD model dryers: the power supply is mis-wired - Line 2 (L2) and Neutral (N) are reversed at the terminal block.
- 008 — On GE GFD model dryers: the door switch is not opening - 5 cycles ran without the door switch opening (displayed as 008 or 00d).
- 009 — On GE GFD model dryers: a drive motor problem - the motor will not run, or will not shut off unless the dryer is unplugged (a stuck relay…
- 00d — On GE GFD model dryers: door switch not opening - the alternate display of code 008, set when 5 cycles ran without the door switch opening.
- E1 — On GE Profile DPVH890 dryers (technical service manual): Interface EEPROM fault - the user interface board is reading or writing its memory…
- E10 — On GE Profile DPVH890 dryers (technical service manual): Blower Motor fault - the blower motor is not rotating properly.
- E101 — On GE Profile DPVH890 dryers (technical service manual): Power EEPROM fault - the power board is reading or writing its memory improperly…
- E11 — On GE Profile DPVH890 dryers (technical service manual): Blocked Airflow - check the ventilation system.
- E12 — On GE Profile DPVH890 dryers (technical service manual): Drum Motor fault - the motor is not rotating properly, or the centrifugal switch…
- E16 — On GE Profile DPVH890 dryers (technical service manual): LIN Communication Failure - a problem with communication between the machine…
- E17 — On GE Profile DPVH890 dryers (technical service manual): VFD Communication Error - a problem with the serial communication interface…
- E18 — On GE Profile DPVH890 dryers (technical service manual): Stuck Button - one or more keys are stuck.
- E2 — On GE Profile DPVH890 dryers (technical service manual): Inlet Short - the inlet thermistor is shorted; check and replace if necessary.
- E3 — On GE Profile DPVH890 dryers (technical service manual): Outlet Short - the outlet thermistor is shorted; check and replace if necessary.
- E4 — On GE Profile DPVH890 dryers (technical service manual): Inlet Open - the inlet thermistor circuit is open; check and replace if necessary.
- E5 — On GE Profile DPVH890 dryers (technical service manual): Outlet Open - the outlet thermistor circuit is open; check and replace if…
- E61 — On GE Profile DPVH890 dryers (technical service manual): Check Electrical Connection - the input voltage is too high; check the power…
- E81 — On GE Profile DPVH890 dryers (technical service manual): Power Model fault - no model select connector was detected; check the model…
- F01 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Inlet thermistor short circuit. The manual advises replacing the…
- F02 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Outlet thermistor short circuit - replace the thermistor or review…
- F03 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Inlet thermistor open circuit - replace the thermistor or review its…
- F04 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Outlet thermistor open circuit - replace the thermistor or review its…
- F05 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): EEPROM error - the manual says to replace the board.
- F06 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Stuck button - set when a button is pressed longer than a minute; if…
- F07 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Mis-wire - the neutral wire is improperly connected; ensure proper…
- F08 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Door Switch Stuck Closed - set when the door has not opened for 5…
- F09 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Long dry times - set when the dryer reaches its maximum cycle time…