Bosch Oven E010 Error Code

What the E010 code means

Data memory error in the user interface on 300, 500 and 800 Series built-in wall ovens: a memory check or write failed and all heating elements are disabled until the error clears at start-up.

Likely causes

  1. failed data memory in the user interface
  2. user interface electronics fault
  3. power interruption during a memory write

How to fix it — step by step

  1. Turn the oven off at the breaker for 30 seconds and restore power to restart it
  2. If the code returns at start-up, stop using the oven
  3. Book a technician - Bosch's service information points to replacing the user interface

Parts that commonly fix the E010 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Bosch oven error codes

See all Bosch oven codes & guides →