Hayward Pool heater Sb Error Code

What the Sb code means

On Hayward Universal H-Series gas pool heaters, Sb means a keypad failure from a stuck button - a button held closed for an extended period.

Likely causes

  1. keypad button stuck closed
  2. debris or moisture on the keypad
  3. failed keypad/display assembly

How to fix it — step by step

  1. Gently press and release each keypad button to free a stuck key
  2. Wipe the keypad clean and dry with power off
  3. Cycle power at the breaker and check if Sb clears
  4. If Sb returns with no button pressed, call a pool/spa technician about the keypad assembly

Parts that commonly fix the Sb code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Hayward pool heater error codes

See all Hayward pool heater codes & guides →