Bosch Dryer E03 Error Code
What the E03 code means
The condensation drainage hose is blocked or kinked, so condensed water cannot drain away (condenser and heat-pump models plumbed to a drain). On some older US models E:03 instead means the maximum drying time was exceeded.
Likely causes
- Drainage hose kinked or trapped
- Hose or siphon spigot blocked with lint or deposits
- Hose installed incorrectly
How to fix it — step by step
- Switch the dryer off and unplug it
- Check the whole condensation drainage hose run for kinks and straighten it
- Loosen the hose clip on the siphon, carefully remove the drainage hose, and clean the hose and the siphon spigot, as Bosch instructs
- Refit the hose securely, restore power and run a short programme to test
- If your model has no drain hose and uses a container, empty the container and clean the fluff filter and condenser instead
Parts that commonly fix the E03 code
- condensation drain hose - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.